MKS E27H.1TBD5B Heated Etch Baratron Sensor
Product Introduction
The E27H.1TBD5B comes from the MKS E27H series of heated etch sensor manometers. This absolute pressure transducer covers a 0.1 Torr full scale range, which targets low-pressure etch process control. Its sensor head stays controlled at 45°C, and this moderate heating limits byproduct deposition inside the measurement cavity. Consequently, the device maintains reliable readings through long etch runs.
Furthermore, the unit is fully interchangeable with earlier 127, 627, and E27 Baratron manometers. This drop-in compatibility simplifies upgrades without mechanical redesign. Meanwhile, the horizontal calibration approach ensures consistent performance after installation in horizontal process lines.
Key Technical Specifications
The E27H.1TBD5B achieves 0.15% of reading accuracy, including non-linearity, hysteresis, and non-repeatability. Resolution reaches 0.001% of full scale for fine low-pressure detection. The analog output provides 0 to +10 VDC into loads above 10 kOhm. Power demand is +/-15 VDC (+/-5%) at 0.25 A maximum, which is modest for a heated sensor.
Specifically, the measurement type is absolute, and the full scale range is 0.1 Torr. A 15-pin D-sub connector with thread locks handles electrical interfacing. The unit offers analog output only, so no trip points are available. Besides, no heater status LED is provided on this configuration.
Mechanical and Environmental Parameters
The E27H.1TBD5B uses an 8 VCR female fitting for leak-tight metal seal connections. Wetted materials are Inconel, which resists corrosive etch chemistries. An integrated sump etch baffle, patented under US #5,822,685, traps byproduct particles away from the diaphragm. Internal volume measures 6.3 cc.
The body diameter is 3.15 in (80.0 mm), with a body height of 3.87 in (98.4 mm) and a stem of 1.38 in (35.1 mm). Operating ambient temperature ranges from 15 to 40°C. Zero temperature coefficient is 0.005% FS/°C, and span temperature coefficient is 0.02% of reading/°C. These values keep output stable during ambient shifts.
Installation Guide
First, confirm that the etch tool line matches the 8 VCR female fitting and that mating glands are clean. Next, mount the E27H.1TBD5B in a horizontal orientation to match its horizontal calibration. Use new metal gaskets for the VCR joint and tighten to the specified torque.
Then, connect the 15-pin D-sub cable and secure the thread locks. Supply +/-15 VDC power within the +/-5% tolerance and verify the 0.25 A maximum draw. Afterward, allow a 4-hour warm-up before critical process measurements. Finally, route the 0 to +10 VDC output to a readout with input impedance above 10 kOhm.
Packaging List
MKS E27H.1TBD5B heated etch Baratron sensor, 1 piece
Protective shipping carton with foam inserts
Product identification label on the body
FAQ
Q1: What full scale range does the E27H.1TBD5B offer?
A: It provides a 0.1 Torr absolute full scale range for low-pressure etch control.
Q2: Why is the sensor heated to 45°C?
A: Moderate heating reduces byproduct deposition and keeps the diaphragm clean during etch processes.
Q3: Is this model compatible with older Baratron units?
A: Yes. It is interchangeable with earlier 127, 627, and E27 Baratron manometers.
Q4: Which fitting and wetted material does it use?
A: It uses an 8 VCR female fitting with Inconel wetted materials.
Q5: How is the E27H.1TBD5B shipped?
A: We ship via Fedex, UPS, and DHL with tracking provided.