The MTL5040 powers one conventional 2-wire 4/20mA transmitter in a hazardous area and repeats its current to a safe-area load. Additionally, it passes a 4/20mA or 0/20mA signal from a safe-area controller to a hazardous-area load. Two channels work independently.
The MTL5044 supplies floating DC power for two conventional 2-wire 4/20mA transmitters in hazardous areas. It also repeats the current through two floating circuits to drive safe-area loads. This unit supports Zone 0, IIC, T4–6 and Div. 1, Group A locations.
The MTL5042 powers conventional 2-wire or 3-wire 4/20mA transmitters located in hazardous areas (Zone 0, IIC, T4-6 or Div.1, Group A). It repeats the current to a safe-area load. For smart 2-wire transmitters, this unit supports bi-directional communications including HART, Honeywell DE, Foxboro, and Yokogawa Brain protocols.
The MTL5041 is a single-channel isolated repeater power supply. It energizes 2-wire 4/20mA transmitters located in hazardous areas (Zone 0, IIC, T4-6 or Div.1, Group A). This module provides a fully-floating DC supply and repeats the current to a safe-area load. It accepts 20-35V DC supply and drives loads from 0 to 1kΩ.
The Pepperl+Fuchs KFD2-STC4-Ex2 is a 2-channel isolated barrier for SMART transmitters. It operates on 24V DC via Power Rail. This device supplies power to 2-wire transmitters in hazardous areas. It repeats the 0/4-20 mA signal to the safe area. Additionally, it supports HART communication and meets SIL2 requirements.
The Pepperl+Fuchs KFD2-RR-EX1 is a 1-channel isolated barrier for resistance thermometers. It operates on 24V DC supply via Power Rail. This device accepts Pt100, Pt500, or Pt1000 inputs. It provides a proportional resistance output with 0.1% accuracy. Additionally, it includes line fault detection and supports SIL2 applications.
The Pepperl+Fuchs KFA5-SR2-Ex1.W.LB is a 1-channel isolated switch amplifier. It operates on 115V AC supply. This device accepts dry contacts or NAMUR sensors. Additionally, it provides a relay output plus a fault relay output. With line fault detection (LFD) and SIL2 rating, it suits safety-related applications in hazardous areas.
The Pepperl+Fuchs KFD2-EB2.R4A.B is a redundant power feed module for the K-System. It ensures continuous operation through dual supply paths. Additionally, this module delivers up to 4A output current. Its fault relay provides reliable system status feedback. Ideal for applications requiring high availability and hazardous area compliance.
The Foxboro FBM214B P0927AH is an 8-channel HART input module. It reads 4-20mA analog signals with HART digital overlay. Each channel is isolated. It works inside the Foxboro I/A Series and Evo systems.
The FBM215 is a high-precision HART output interface module from Foxboro. It provides eight isolated output channels for HART-compliant instruments. Each channel supports point-to-point communication at 1200 baud. The module works with HART versions 5, 6, and 7. Analog accuracy reaches ±0.05% between 4 mA and 20 mA.
The FBM216 is a high-precision HART input interface module from Foxboro. It provides eight individually isolated channels for HART-compliant instruments. Each channel supports point-to-point communication at 1200 baud. The module works with HART versions 5, 6, and 7. You can use it in redundant configurations for critical applications.
The FBM230 is a versatile Modbus Master driver from Foxboro. It supports both serial and TCP/IP communication. Each of its four ports is software-configurable for RS-232, RS-422, or RS-485. This flexibility allows connection to various field devices. You can integrate up to 64 RS-485 devices or four direct RS-232/RS-422 devices.