Main image of Woodward 5464-334 4-20mA 8-Channel Isolated Input Module

Woodward 5464-334 4-20mA 8-Channel Isolated Input Module

5464-334
Manufacturer: Woodward
Series: 5400 Series
Model Number: 5464-334
Weight: 0.91 kg
Condition: In Stock
Availability: 100% Original Brand New
Product Origin: USA
Shipping port: Xiamen
Warranty: 12 Month

Product Introduction

The Woodward 5464-334 is a smart isolated analog input module for turbine control systems.

It accepts 4–20mA field signals and delivers accurate, interference-free measurements.

Each channel uses electrical isolation to protect against noise and ground loops.

Additionally, the module includes an onboard microcontroller for independent operation.

It performs self-testing, fault detection, and automatic calibration without heavy CPU load.

A status LED clearly indicates normal operation or I/O fault conditions.

Moreover, the unit supports a wide power supply range and extreme temperatures.

It has a visible external fuse for safe and quick maintenance.

This module ensures reliable signal acquisition in harsh industrial environments.

Core Electrical Specifications

The Woodward 5464-334 supports 8 isolated analog input channels for 4–20mA signals.

It offers 3000 VDC isolation between channels and system circuits.

The module runs on a 10–60 VDC power supply range.

It also accepts a 24 VDC logic input and has a maximum operating current of 12V.

High isolation voltage improves safety and signal stability in noisy environments.

Each channel delivers precise and consistent analog measurement.

Environmental & Mechanical Parameters

This module operates from -25°C to +70°C for extreme industrial conditions.

It measures 30 cm × 20 cm × 25 cm and weighs only 0.8 kg.

The compact size allows easy installation in standard control chassis.

Furthermore, the unit meets US manufacturing quality standards.

Its rugged construction withstands vibration and electrical interference.

It is designed for long-term use in turbine and power generation systems.

Intelligent I/O & Fault Detection

The Woodward 5464-334 uses an onboard microcontroller for smart signal processing.

It manages independent scheduling and reduces CPU intervention during operation.

Every minute, it reads a precision voltage reference during idle periods.

The system compares readings to predefined thresholds for fault detection.

Out-of-range values trigger channel-specific fault alerts for the CPU.

Faults may indicate issues with the input, A/D converter, or voltage reference.

Automatic Calibration & Compensation

Besides fault detection, the module performs automatic temperature compensation.

Reference data calibrates signal accuracy and maintains long-term stability.

This feature eliminates manual adjustment and ensures measurement consistency.

Additionally, the module supports real-time output monitoring for actuator signals.

It detects abnormal voltage or current and sends immediate fault notifications.

Such functions improve system safety and reduce unplanned downtime.

Installation & Safety Features

The module integrates a visible external fuse for easy inspection and replacement.

Technicians can quickly swap a blown fuse with an identical rated unit.

During power-up, the module runs self-tests and turns off the LED when ready.

An illuminated LED signals an I/O fault for fast on-site diagnosis.

The module connects securely to the system backplane and field wiring terminals.

Proper installation ensures stable communication and accurate signal acquisition.

Packaging List

  • 1 × Woodward 5464-334 Isolated Analog Input Module
  • Standard mounting hardware
  • Fuse replacement set
  • Channel identification label sheet

FAQ

  1. What is the Woodward 5464-334 used for?

    It is an 8-channel isolated analog input module for 4–20mA signals in turbine control systems.

  2. What isolation voltage does the module provide?

    It offers 3000 VDC isolation between input channels and control circuits.

  3. What power supply range does the 5464-334 support?

    It operates on a wide voltage range of 10–60 VDC.

  4. Does the module support automatic calibration?

    Yes, it uses an onboard microcontroller for automatic calibration and temperature compensation.

  5. How does the module indicate faults?

    A front LED lights up to signal I/O faults, channel errors, or abnormal operating conditions.

Shipping: Fedex, UPS, DHL


Attention: The above product information is sourced from the internet and cannot be guaranteed to be authentic. For specific product parameters and prices, please contact SpareTech PLC professionals in a timely manner.
Brand NameWoodward
Model No.5464-334
Product TypeIsolated Analog Input Module
hasMerchantReturnPolicyAdjust according to reality
ShippingdetailsAdjust according to reality
The Woodward 5464-334 is an 8-channel isolated analog input module for 4–20mA signals. It provides 3000 VDC isolation, wide power input, and intelligent fault detection. It supports stable signal measurement in turbine control systems with automatic calibration and temperature compensation.
SpareTech PLC provides you with a PDF version of the instructions about Woodward 5464-334, where you can download the Woodward 5464-334 manual PDF for free:
Download PDF

Get a Professional Quote