TM2DMM16DRTN
Manufacturer: Schneider Electric Series: Modicon M238 Model Number: TM2DMM16DRTN Weight: 0.12kg Condition: In Stock Availability: 100% Original Brand New Product Origin: FR Shipping port: Xiamen Warranty: 12 Month
TM2DMM16DRTN Mixed I/O Module with 8 Inputs and 8 Outputs
Product Introduction
The Schneider Electric TM2DMM16DRTN gives you both inputs and outputs in one module. You get 8 digital input channels and 8 relay output channels. This mixed design saves space in your control cabinet. Additionally, it reduces the number of modules you need for small to medium applications.
The inputs accept 24V DC signals. They work with both sink and source wiring. The outputs use relay contacts rated for 2A at either 24V DC or 220V AC. Therefore, you can switch both DC and AC loads with the same module.
Power comes through the ribbon cable from the controller. A removable screw terminal block makes wiring simple and fast. Green LEDs show the status of each input and output. A red LED alerts you to configuration or internal errors.
Technical Specifications
Input Specifications
Number of Inputs: 8 Input Type: Type 1 (compatible with IEC 61131-2) Input Signal Type: Sink or source (selectable by wiring) Rated Input Voltage: 24V DC Input Status Indication: Green LED per channel
Output Specifications
Number of Outputs: 8 Output Type: Relay, normally open (NO) Output Voltage/Current (DC): 24V DC at 2A maximum Output Voltage/Current (AC): 220V AC at 2A maximum Output Status Indication: Green LED per channel
General Specifications
Connection Type: Removable screw terminal block Power Supply: Via ribbon cable from controller Mounting Support: 35mm DIN rail Product Weight: 0.12 kg (0.26 lb)
LED Status Indicators
Expansion Module Status LEDs
LED
Color
Function
Status Meaning
PWR
Green
Power
ON solid = device powered on. OFF = no power.
ERR
Red
Error detection
ON solid = internal error. Flashing = module not configured. OFF = no error.
I/O Status LEDs
LED Type
Color
Status Meaning
Digital input LED
Green
ON solid = input active. OFF = input inactive.
Digital output LED
Green
ON solid = output active. OFF = output inactive.
Mechanical & Environmental Data
Mounting: 35mm symmetrical DIN rail Electrical Connection: 1 removable screw terminal block Local Signalling: PWR (green), ERR (red), plus 16 green I/O status LEDs Range Compatibility: Modicon M238 logic controller, Twido, Advantys OTB
Installation Guidelines
First, turn off all power to the controller. Mount the TM2DMM16DRTN on a 35mm DIN rail. Push it until the clip locks into place.
Next, connect the ribbon cable from the controller or previous module. This provides both power and communication. Then, wire your field devices to the removable screw terminal block. For inputs, you can choose sink or source wiring. Connect the 24V DC common accordingly.
For outputs, remember that relay contacts are isolated. You can mix AC and DC loads on different outputs. However, do not exceed 2A per channel or 8A per common.
After wiring, push the terminal block back into the module. Apply power and check the green PWR LED. If the red ERR LED flashes, configure the module in your software. Finally, test each input and output while watching the green status LEDs.
Packaging List
1 x Schneider Electric TM2DMM16DRTN mixed I/O module
1 x Removable screw terminal block
1 x Quick reference card
Note: No certificates or warranty documents are included in the package.
Shipping
We ship worldwide via Fedex, UPS, or DHL. All orders include tracking information.
Frequently Asked Questions (FAQ)
1. Which controllers work with the TM2DMM16DRTN? The TM2DMM16DRTN works with Modicon M238 logic controllers, Twido series, and Advantys OTB systems. It connects via the standard expansion ribbon cable.
2. Can I use AC loads on some outputs and DC loads on others? Yes, you can. Each relay output is isolated. This means you can connect 24V DC loads to some outputs and 220V AC loads to others. Just keep each output within the 2A rating.
3. Why is the red ERR LED flashing on my TM2DMM16DRTN? A flashing red ERR LED means the module is not configured. Open your programming software (SoMachine or TwidoSuite). Add the TM2DMM16DRTN to the I/O configuration. Then download the new configuration to the controller.
4. How do I select sink or source wiring for the inputs? The TM2DMM16DRTN inputs work with both sink and source. For sink wiring, connect the sensor output to the input terminal. Connect the common to 0V. For source wiring, connect the sensor output to the input terminal. Connect the common to 24V. The LED lights up when the input is active.
5. What is the lifespan of the relay outputs? The mechanical lifespan is 20 million cycles. The electrical lifespan depends on your load. For a 2A resistive load at 240V AC, expect 100,000 cycles. For inductive loads, the lifespan will be lower. Use external protection like snubbers or varistors for long relay life.
Attention: The above product information is sourced from the internet and cannot be guaranteed to be authentic.
For specific product parameters and prices, please contact
SpareTech PLC professionals in a timely manner.
Brand Name
Schneider Electric
Model No.
TM2DMM16DRTN
Product Type
Mixed I/O Expansion Module
hasMerchantReturnPolicy
Adjust according to reality
Shippingdetails
Adjust according to reality
The Schneider Electric TM2DMM16DRTN is a compact mixed I/O expansion module. It combines 8 digital inputs (24V DC, type 1, sink/source) with 8 relay outputs (2A at 24V DC or 220V AC). This unit includes a removable screw terminal block and clear status LEDs. Ideal for Modicon M238 and Twido controllers. SpareTech PLC provides you with a PDF version of the instructions about
Schneider Electric TM2DMM16DRTN,
where you can download the
Schneider Electric TM2DMM16DRTN manual PDF for free: Download PDF