Lenze E94ASHE0034 – Multi-Voltage Drive for Precision Motion Control
The Lenze E94ASHE0034 belongs to the high-performance Series 9400. This drive accepts three different input voltages: 230 VAC, 400 VAC, or 500 VAC. All are three-phase at 50/60 Hz. Consequently, one part number works across multiple global power systems.
Rated output power is 0.75 kW. The drive delivers an output voltage from 0 up to the supplied line voltage. Output frequency ranges from 0 to 480 Hz, which suits both standard and high-speed motors.
Key Technical Parameters
Here are the critical electrical ratings for the E94ASHE0034:
Input current: 3.3 A at 230 VAC / 3.5 A at 400 VAC / 3.1 A at 500 VAC
Switching frequency: 8 kHz (fixed)
Overload capacity: 150% for 60 seconds
Braking chopper: Integrated internally
Control modes: Speed, torque, and position
Feedback support: Incremental encoder, resolver, absolute encoder
Additionally, the Lenze 9400 series includes high-precision current control loops. For this reason, the E94ASHE0034 performs well in dynamic applications like pick-and-place, winding, and indexing.
Mechanical and Environmental Specifications
The unit has an IP20 protection class. Therefore, it must be installed inside a control cabinet. Cooling uses forced ventilation with an internal fan. Key mechanical details:
Dimensions: 90 x 250 x 195 mm (W x H x D)
Weight: Approx. 2.9 kg net
Operating temperature: 0°C to 40°C without derating
Storage temperature: -25°C to +70°C
Humidity: Max 95%, non-condensing
Furthermore, the drive complies with CE, UL, and cUL standards. This ensures safety for worldwide export.
Communication and Integration
The E94ASHE0034 supports multiple fieldbus options depending on the installed module. Common choices include:
CANopen
PROFIBUS DP
EtherCAT
Meanwhile, the drive includes standard digital and analog I/Os. For instance, there are 4 digital inputs, 2 digital outputs, and 2 analog inputs. You can configure these for local interlocking without a PLC.
Installation Guidelines
First, mount the Lenze E94ASHE0034 vertically on a non-flammable surface. Use M4 screws in all four corners. Next, maintain 80 mm clearance above and below the unit. This allows proper airflow through the forced ventilation system.
For wiring, separate power cables from signal cables by at least 100 mm. Specifically, use shielded feedback cables with grounds connected at both ends. Moreover, install a mains filter upstream if other sensitive equipment shares the same supply.
Finally, perform the first startup without motor load. Use Lenze Engineer software or the integrated keypad. Set motor parameters based on the nameplate data. Then, run an autotuning cycle for optimal performance.
Typical Applications
The E94ASHE0034 handles many industrial tasks. For example:
Small packaging machines
Labeling units
Conveyor synchronization
Rotary tables
Tension control systems
Because it supports three control modes, the same drive works for speed-controlled fans and position-controlled axes.
Packaging List
Lenze E94ASHE0034 drive unit – 1 piece
Control terminal connector (removable)
Power terminal cover
Quick start guide (multilingual)
Safety warning sheet
Note: Fieldbus modules, feedback cables, and braking resistors are sold separately.
Shipping
All orders are dispatched via Fedex, UPS, or DHL. Tracking information is sent by email after shipment.
Frequently Asked Questions (FAQ)
1. Can the Lenze E94ASHE0034 run on single-phase power?
No. This drive requires three-phase input. Single-phase operation will cause undervoltage faults.
2. What software do I need to configure the E94ASHE0034?
Use Lenze Engineer (free download) or the optional keypad module. Both tools access all parameters.
3. Does the Series 9400 drive support safe torque off (STO)?
Yes, but only with an optional safety module. The base E94ASHE0034 does not include STO by default.
4. How do I reset an overload fault on the Lenze E94ASHE0034?
Wait for the drive to cool down. Then, cycle the 24 V DC control supply. Alternatively, send a reset command via fieldbus.
5. What is the maximum motor cable length for this drive?
Shielded cable: up to 25 meters. Unshielded cable: up to 50 meters. For longer runs, add an output reactor.