IC660BBD025 5/12/24 VDC 32-Circuit Sink I/O Block
Product Introduction
The IC660BBD025 is a flexible sink I/O block designed for distributed control systems. It connects controllers to field devices like proximity switches and sensors. This module supports both 2-wire and 3-wire devices. Additionally, it works with +5 volt TTL logic. You can configure each of its 32 circuits as input, output, or output with feedback.
Technical Specifications
The IC660BBD025 accepts input signals at 5, 12, or 24 VDC. Input processing time is 1.4 ms. Outputs handle a steady-state load of 0.5 Amperes per circuit. Maximum inrush current reaches 4 Amperes for up to 10 ms.
Block-to-block isolation is rated at 850 Volts. Heat dissipation measures 11 Watts with 8 inputs active and 18 Watts with all 32 inputs on. The module also includes resettable self-protecting circuits.
Key features include:
Output Pulse Test capability
Selectable Input Filter Time (1 to 100 ms)
CPU Redundancy support
Output Hold behavior configuration
Ready for Bus Switching Module control
Mechanical and Environmental Data
Dimensions (H x W x D): 8.83 x 3.58 x 4.7 inches
Operating Temperature: 0°C to 60°C
Storage Temperature: -40°C to 100°C
Humidity: 5-95% non-condensing
Compatible terminal base: IC660TBD025
Compatible electronics assembly: IC660EBD025
Installation Guidelines
For proper installation, use a protective case. Choose a location free of airborne contaminants. Ensure adequate cooling and airflow around the block.
Ground screws must connect to a reliable grounding system. Wire the block power disconnects so block power and input power remove at the same time. This prevents unexpected power-up when multiple inputs are active.
Terminals 5 through 46 are for field device connections. Furthermore, you can configure the IC660BBD025 using a handheld monitor. The monitor also works with onboard LEDs to check status quickly.
Built-In Diagnostics and Protection
The IC660BBD025 ships with block diagnostics that monitor output and compare actual switch state to the commanded state. Output diagnostics include failed switch detection.
Short circuits caused by wiring errors are protected at the driver circuit level. Overload and overtemperature protection are also integrated.
Why Choose This Module?
This Genius I/O block supports remote installation up to 7500 feet from the controller. It integrates directly with Series 90-30 and Series 90-70 controllers. Third-party devices supporting the Genius protocol also work with it.
Moreover, the IC660BBD025 provides LED indicators for Module OK and I/O Enabled. Individual LEDs light up when each I/O point is used.
Packaging List
Note: No certificates or warranty documents are included.
Shipping
We ship via FedEx, UPS, or DHL. Tracking number provided after dispatch.
Frequently Asked Questions (FAQ)
1. Can the IC660BBD025 work as both input and output on different circuits?
Yes. Each of the 32 circuits is independently configurable as input, output, or output with feedback.
2. What happens if a field output device needs to supply current instead of receiving it?
For sourcing current to field devices, use the IC660BBD024 source block instead of the IC660BBD025.
3. Is the IC660BBD025 compatible with TTL signals?
Absolutely. It supports +5 volt TTL logic, making it ideal for digital systems.
4. How do I configure the input filter time?
Use a handheld monitor connected to the block. Selectable filter times range from 1 ms to 100 ms.
5. Can I use this block with a redundant CPU setup?
Yes. The IC660BBD025 includes CPU Redundancy type as a configurable feature.