The Eaton MTL5314 is a single-channel trip amplifier for 2- or 3-wire 4-20mA transmitters. It supplies two configurable alarm signals via changeover relays. Each relay triggers independently when the input exceeds or falls below a setpoint. HART communication passes through without interruption. Ideal for Zone 0 and SIL applications.
The Eaton MTL5514D is a single-channel switch/proximity detector interface from the MTL5500 series. It accepts digital inputs from hazardous area sensors and provides two relay outputs. This isolator supports line fault detection (LFD) and phase reversal. Ideal for Zone 0, Zone 2, and SIL2/SIL3 safety loops.
The Eaton Crouse-Hinds MTL5511 is a single-channel isolator for switch or proximity detector inputs. It provides a 7-9Vdc sensor supply and features a relay contact output rated for Zone 2 hazardous areas. With SIL2/SIL3 certification and line fault detection, it suits safety-related applications.
The Eaton Crouse-Hinds MTL5513 is a two-channel isolator for switch or proximity detector inputs. It provides a 7-9V sensor supply and accepts digital signals from hazardous areas. Each channel features independent phase reversal and line fault detection with red LFD indication.
The Eaton Crouse-Hinds MTL5573 is a single-channel temperature converter for RTD or thermocouple inputs. It delivers a 4-20mA output with 500ms response time. Designed for Zone 0 hazardous areas, it includes galvanic isolation, early burnout detection, and configurable sensor failure behavior.
The Eaton Crouse-Hinds MTL5575 is a single-channel temperature converter designed for hazardous areas. It accepts thermocouple, RTD, or mV inputs and provides a 4-20mA output. With galvanic isolation and alarm functionality, it suits Zone 0 installations and offers reliable signal conditioning
The Eaton MTL5561 is a loop-powered two-channel interface for conventional fire and smoke detectors in hazardous areas. When a detector triggers, the safe-area current changes accordingly. This unit includes reverse input polarity protection. It suits Zone 0, IIC, T4–6 locations and Division 1, Group A hazardous areas.
The Eaton MTL5546 is an isolating driver for 4-20mA smart valve positioners. It accepts a floating signal from a safe-area controller. This unit drives loads up to 800Ω in Zone 0 hazardous areas. Additionally, it supports HART communication for bidirectional digital signals. Line fault detection helps operators identify open or short circuits in field wiring.
The MTL5581 from Eaton’s MTL5500 Series isolates low-level millivolt and thermocouple signals. It supports Zone 0 hazardous areas. This unit offers fast 150µs response and precise ±5µV accuracy. A reliable choice for temperature signal conditioning.
The MTL5522 is a loop-powered solenoid or alarm driver from Eaton's MTL5500 series. It provides a digital output for hazardous area applications. This unit supports Zone 0 locations with IECEx/ATEX approval. Its loop-powered design reduces wiring complexity. The compact housing fits a standard 35mm DIN rail.
The MTL5532 is a single-channel pulse isolator from Eaton’s MTL5500 series. It accepts pulse or vibration inputs from hazardous areas. This unit provides isolated 4-20mA or pulse outputs. Moreover, it supports Zone 0 locations with IECEx/ATEX approval. Configuration is easy using a PC with MTL PCS45 software.
The Eaton Crouse-Hinds series MTL5525 is a single-channel digital output driver for solenoids and alarms. It operates in hazardous locations up to Zone 0. With galvanic isolation and low power consumption, this unit supports SIL2 and SIL3 applications safely.