RA890G1245 Honeywell Protectorelay™ Primary Control

Product Introduction

The RA890G1245 belongs to Honeywell’s Protectorelay™ series. This primary flame safety control supervises oil and gas burners. It operates on 220V power at either 50 or 60 Hz. A 15-second safety switch timing locks out the system upon flame failure. Flame response occurs within 0.8 seconds. Additionally, this model includes isolated SPDT alarm contacts. Therefore, you can connect external warning lights or buzzers. The RA890G1245 mounts on a Q270A universal subbase (sold separately). It works seamlessly with C7027, C7035, or C7044 ultraviolet flame detectors.

Technical Specifications

Electrical Ratings

The RA890G1245 accepts 220V at 50 or 60 Hz. Power consumption is modest. At 60 Hz, maximum draw is 14 VA with 12 VA in standby. At 50 Hz, maximum reaches 18 VA with 17 VA standby. Meanwhile, actual wattage stays low: 9.5W max (60 Hz) and 3W standby, or 10W max (50 Hz) and 4W standby. Consequently, this controller suits energy-conscious installations.

Safety Switch and Flame Response

Safety switch timing is nominally 15 seconds. However, under certain conditions, timing may extend up to 50 seconds. Specifically, voltages between 70 and 110 percent of rated value and ambient temperatures from 32°F to 115°F (0°C to 66°C) allow this variance. Flame failure response triggers almost immediately after the flame establishing period ends. The flame establishing period itself can reach 15 seconds. Furthermore, the recycle function activates nearly instantly after flame failure response.

Alarm Contacts

A key feature of the RA890G1245 is its isolated SPDT alarm contacts. These terminals use male quick-connects. For convenience, female quick-connects come included for field installation. You can wire these contacts to external alarms, indicator lights, or building management systems. Thus, operators receive immediate notification of flame faults.

Flame Detector Compatibility

This primary control works exclusively with Honeywell ultraviolet flame detectors. Compatible models include:

  • C7027 UV detector

  • C7035 UV detector

  • C7044 UV detector

When paralleling two flame detectors, always refer to the appropriate detector instructions. Proper wiring ensures reliable flame supervision.

Mechanical and Environmental Parameters

Dimensions and Mounting

The RA890G1245 measures approximately 5 x 5 x 5 inches (127 x 127 x 127 mm) including the subbase. It requires a Q270A universal mounting base, which is ordered separately. The cover includes a thumb screw for easy access. A reset pushbutton sits on the front panel. Additionally, a flame current test jack allows field verification of detector performance.

Terminal Blocks and Connections

Terminal blocks are clearly marked on the RA890G1245 base. For line voltage controller applications, connect the controller between the limit control and terminal 6. Then, jumper T-T. For low voltage controllers, follow the standard wiring diagram. The load relay (1K) and flame relay (2K) are internal components. An M8720 transformer (TR2) and another transformer (TR1) complete the power section.

Ambient Temperature Ratings

Minimum ambient temperature depends on safety switch timing. Models with a 15-second safety switch, like the RA890G1245, operate down to -20°F (-29°C). Maximum temperature varies by alarm contact presence and frequency. For units with alarm contacts at 50 Hz, maximum is 105°F (41°C). At 60 Hz with alarm contacts, maximum reaches 115°F (46°C). Therefore, proper ventilation is important in hot boiler rooms.

Installation Guidelines

First, mount the Q270A universal subbase on a flat, non-combustible surface. Next, connect power leads to the appropriate terminals on the RA890G1245 base. Then, install the chosen UV flame detector (C7027, C7035, or C7044) according to its manual. After that, wire the SPDT alarm contacts if external notification is needed. Furthermore, connect the burner motor and ignition circuits through the load relay terminals.

For line voltage controller setups, place the controller between the limit control and terminal 6. Remember to install a jumper across T-T. For paralleling two flame detectors, follow the specific detector instructions carefully. Finally, secure the RA890G1245 cover using the thumb screw. Perform a flame current test using the test jack before putting the system into service.

Packaging List

  • RA890G1245 Protectorelay™ primary control unit (cover and base assembly)

  • Female quick-connects for SPDT alarm terminals (field installation)

  • Installation instruction sheet

  • Wiring diagram label

  • Flame current test jack cover

Note: No certificates, warranty documents, or Q270A subbase are included. The subbase and flame detectors are sold separately.

Shipping Method: Fedex, UPS, DHL

Frequently Asked Questions (FAQ)

1. Which flame detectors work with the RA890G1245?
The RA890G1245 works exclusively with Honeywell C7027, C7035, or C7044 ultraviolet flame detectors.

2. Do I need to buy the subbase separately?
Yes. The Q270A universal mounting base is ordered separately and not included with the RA890G1245.

3. How do I test flame current on this controller?
Use the flame current test jack located on the RA890G1245 cover. Insert a compatible meter to read the signal.

4. What causes the safety switch to lock out?
The 15-second safety switch locks out when the flame detector fails to sense a flame within the establishing period.

5. Can I use this controller with two flame detectors?
Yes. You can parallel two UV detectors. Refer to the detector instructions for proper wiring methods.



Attention: The above product information is sourced from the internet and cannot be guaranteed to be authentic. For specific product parameters and prices, please contact SpareTech PLC professionals in a timely manner.
Brand Name Honeywell
Model No. RA890G1245
Product Type Primary Flame Safety Control
hasMerchantReturnPolicy Adjust according to reality
Shippingdetails Adjust according to reality
The Honeywell RA890G1245 Protectorelay™ primary control manages flame supervision in commercial and industrial burners. It operates on 220V at 50/60Hz. A 15-second safety switch provides lockout timing. Flame response takes only 0.8 seconds. The SPDT alarm contacts enable external alert systems. This model works with C7027, C7035, or C7044 ultraviolet flame detectors.
SpareTech PLC provides you with a PDF version of the instructions about Honeywell RA890G1245, where you can download the Honeywell RA890G1245 manual PDF for free:
Download PDF

Get a Professional Quote