Product Description

The CI801 Fieldbus Communication Interface module links S800 I/O systems to higher‑level controllers.

It uses the PROFIBUS‑DPV1 protocol for reliable industrial communication across process plants.

This module manages signal processing, supervision, OSP handling, and I/O module configuration.

It provides galvanically isolated power to connected I/O modules for improved noise immunity.

HART pass‑through functionality enables HART device management over the same bus.

Hot Configuration In Run allows parameter changes without stopping system operation.

The module includes fused input power protection for safe and stable operation.

The CI801 is widely used in process industries with marine and hazardous area approvals.

Technical Specifications

The CI801 operates as a PROFIBUS DP‑V1 slave on industrial fieldbus networks.

It supports full supervision of the I/O ModuleBus for system diagnostics.

Isolated power output protects connected I/O modules from electrical interference.

Typical 24 V DC power consumption is 140 mA under normal operating conditions.

The module supports HART pass‑through for smart field device communication.

Hot Configuration In Run allows online setup changes without process interruption.

Input power is fused to prevent damage from overcurrent or short‑circuit events.

It is designed for use with ABB HI Controller systems in distributed I/O architectures.

No line or module redundancy is provided in this standard model.

Hot‑swap functionality is not supported by the CI801 module design.

Environmental & Safety Certifications

The CI801 carries CE marking and complies with EN 61010‑1 and UL 61010‑1.

Hazardous location approvals include Class I Div 2, Zone 2, and ATEX Zone 2.

Marine certifications include ABS, BV, DNV‑GL, and LR for shipboard applications.

Operating temperature range is 0 °C to +55 °C (certified for +5 °C to +55 °C).

Storage temperature spans ‑40 °C to +70 °C for transport and long‑term storage.

Pollution degree is rated 2 per IEC 60664‑1 for industrial environments.

Corrosion protection meets ISA‑S71.04 G3 harsh environment standards.

Relative humidity tolerance is 5% to 95% non‑condensing.

Protection class is IP20 per EN 60529 and IEC 529.

The module complies with RoHS 2011/65/EU and WEEE 2012/19/EU directives.

Mechanical Specifications

Width of the CI801 is 85.8 mm (3.38 in.) for standard cabinet mounting.

Height including latch is 136 mm (5.35 in.) for rack installation.

Depth measures 58.5 mm (2.30 in.) to fit compact control panels.

Net weight is 0.3 kg (0.66 lbs.) for lightweight modular installation.

Installation Guide

Mount the CI801 in a suitable S800 I/O rack or mounting position.

Connect 24 V DC fused power to the module input terminals carefully.

Attach the PROFIBUS‑DPV1 fieldbus cable to the communication port.

Ensure proper bus termination and grounding per ABB installation guidelines.

Wire I/O ModuleBus connections to downstream S800 I/O modules securely.

Verify environmental conditions stay within 0 °C to +55 °C during operation.

Maintain vertical mounting temperature limits at or below 40 °C where applicable.

Configure bus address and communication parameters via system software tools.

Confirm HART pass‑through and hot configuration settings before operation.

Perform a system test to validate communication and I/O module control.

Packing List

  • 1 × ABB CI801 Communication Interface Module
  • 1 × Installation and Configuration Document
  • Anti‑static protective bag
  • Product identification label
Shipping methods: FedEx, UPS, DHL.

Frequently Asked Questions

1. What protocol does the CI801 use?

The CI801 uses PROFIBUS‑DPV1 as its fieldbus communication protocol.

2. Is the module suitable for hazardous areas?

Yes, it is approved for Class I Div 2, Zone 2, and ATEX Zone 2 hazardous locations.

3. Does CI801 support HART pass-through?

Yes, the CI801 includes full HART pass‑through functionality.

4. What is the power requirement of this module?

It uses 24 V DC with a typical current consumption of 140 mA.

5. Does the module have marine certifications?

Yes, it holds ABS, BV, DNV‑GL, and LR marine type approvals.


Attention: The above product information is sourced from the internet and cannot be guaranteed to be authentic. For specific product parameters and prices, please contact SpareTech PLC professionals in a timely manner.
Brand NameABB
Model No.CI801
Product Type Fieldbus Communication Interface (FCI)
hasMerchantReturnPolicyAdjust according to reality
ShippingdetailsAdjust according to reality
The CI801 is a PROFIBUS-DPV1 communication interface module for ABB S800 I/O systems. It acts as a fieldbus slave connecting I/O modules to a controller. It supports HART pass‑through, hot configuration, isolated power, and holds ATEX, marine, and hazardous location certifications.
SpareTech PLC provides you with a PDF version of the instructions about ABB CI801, where you can download the ABB CI801 manual PDF for free:

Get a Professional Quote