Home /
Products /
Bently Nevada 3300/12-01-20-00 AC Power Supply
Bently Nevada 3300/12-01-20-00 AC Power Supply
3300/12-01-20-00
Manufacturer: Bently Nevada Series: 3300 Series Model Number: 3300/12-01-20-00 Weight: 1 kg Condition: In Stock Availability: 100% Original Brand New Product Origin: U.S.A Shipping port: Xiamen Warranty: 12 Month
The 3300/12-01-20-00 is a high-performance AC power supply designed specifically for Bently Nevada’s 3300 series monitoring racks. It provides stable, regulated power to keep critical monitoring systems running smoothly in industrial settings. This unit eliminates the need for a second power supply in the same rack, saving space and reducing installation costs.
It installs in the left-most position (position 1) of a 3300 rack and converts AC input voltage into the DC voltages required by the rack’s monitors. A built-in line noise filter comes standard, ensuring clean power delivery and protecting sensitive monitoring equipment from electrical interference. This filter is essential for maintaining accurate readings and reliable operation in noisy industrial environments.
The 3300/12-01-20-00 is built to withstand harsh industrial conditions, with robust construction that ensures long-term durability. It supports field-adjustable input voltage, allowing flexibility to adapt to different power sources without replacing the entire unit. This adaptability makes it suitable for global industrial applications with varying power standards.
Technical Specifications
Input Specifications
Input Voltage Range: 95 to 125 Vac (single phase, 50-60 Hz) or 190 to 250 Vac (single phase, 50-60 Hz)
Maximum Input Current: 1.0 A (for 95-125 Vac) or 0.5 A (for 190-250 Vac)
Input Voltage Adjustment: Field-changeable via soldered jumper and external fuse replacement
Primary Power Surge (Powerup): 26 A peak or 12 A rms for one cycle
Fuse Rating: 1.5 A slow blow (95-125 Vac); 0.75 A slow blow (190-250 Vac)
Output Specifications
Transducer Power (Internal to Rack): User-programmable to -24 Vdc (+0%, -2.5%) or -18 Vdc (+1%, -2%)
Overload Protection: Transducer voltages are overload protected per channel on individual monitor circuit boards
OK Relay: Single-pole, double-throw (SPDT), hermetically-sealed
OK Relay Location: Behind the power supply, at the Power Supply Input Module
OK Relay Contact Ratings (Resistive Load): 5 A at 28 Vdc; 5 A at 120 Vac (50/60 Hz); 3 A at 220 Vac (50/60 Hz)
OK Relay Ratings (Agency Approval): 5 A at 28 Vdc; 5 A at 120 Vac (50/60 Hz); 30 Vac for ATEX
OK Relay Contact Life: Minimum 10,000 cycles at rated load
OK Relay Operation: Normally energized
Environmental Limits
Operating Temperature: 0°C to +65°C (+32°F to +150°F)
Storage Temperature: -40°C to +85°C (-40°F to +185°F)
Relative Humidity: Up to 95%, noncondensing
Installation Guide
Ensure the 3300 rack is powered off and disconnected from all power sources before installation.
Locate the left-most position (position 1) in the 3300 rack, which is reserved for the power supply.
Align the 3300/12-01-20-00 with the rack rails and slide it into position until it locks securely.
Connect the AC input power cable to the appropriate terminals on the power supply.
Verify the input voltage setting matches your power source (95-125 Vac or 190-250 Vac).
If needed, adjust the input voltage via the soldered jumper and replace the external fuse accordingly.
Connect the rack’s monitor circuit boards to the power supply’s output terminals.
Ensure all connections are tight and secure to prevent electrical issues or signal interference.
Power on the rack and check the OK relay status to confirm proper operation.
Verify that all monitors and transducers receive stable power from the 3300/12-01-20-00.
Packing List
1 × Bently Nevada 3300/12-01-20-00 AC Power Supply
1 × Installation Manual
Anti-static protective bag
Product identification label
Shipping available via FedEx, UPS, DHL.
Frequently Asked Questions (FAQs)
How many monitors can the 3300/12-01-20-00 power?
The 3300/12-01-20-00 can deliver reliable power for up to 12 monitors and their associated transducers, so no second power supply is needed in the same rack.
Can I adjust the input voltage of the 3300/12-01-20-00?
Yes, the input voltage is field-changeable. You can adjust it via a soldered jumper and replacement of the external fuse to match 95-125 Vac or 190-250 Vac.
What is the operating temperature range of the 3300/12-01-20-00?
It operates reliably between 0°C to +65°C (+32°F to +150°F), suitable for most industrial environments.
What type of relay does the 3300/12-01-20-00 have?
It has a hermetically-sealed single-pole, double-throw (SPDT) OK relay that is normally energized.
Where should I install the 3300/12-01-20-00 in a 3300 rack?
It must be installed in the left-most location (position 1) of the 3300 rack to ensure proper power distribution to all monitors.
Attention: The above product information is sourced from the internet and cannot be guaranteed to be authentic.
For specific product parameters and prices, please contact
SpareTech PLC professionals in a timely manner.
Brand Name
Bently Nevada
Model No.
3300/12-01-20-00
Product Type
AC Power Supply
hasMerchantReturnPolicy
Adjust according to reality
Shippingdetails
Adjust according to reality
The 3300/12-01-20-00 is a reliable regulated AC power supply from Bently Nevada. It powers up to 12 monitors and their transducers in a 3300 series rack, converts AC to DC, and includes a standard line noise filter. The 3300/12-01-20-00 needs no second power supply and installs in the left-most rack position. SpareTech PLC provides you with a PDF version of the instructions about