Bently Nevada 330106-05-30-10-02-05 3300 XL 8mm Reverse Mount Probe
Product Introduction
The Bently Nevada 330106-05-30-10-02-05 belongs to the 3300 XL 8 mm reverse mount probe family. This model uses M10 x 1 threads instead of the common 3/8-24 option. Its 1.0-meter (3.3 feet) total length suits compact machinery installations. The -02 connector option provides a miniature ClickLoc coaxial connector. Agency approval option 05 includes CSA, ATEX, and IECEx certifications for hazardous areas.
Technical Specifications
The Bently Nevada 330106-05-30-10-02-05 features a Polyphenylene sulfide (PPS) probe tip. The probe case uses AISI 303 or 304 stainless steel (SST). Maximum thread engagement length for M10x1 threads is 15 mm.
Nominal probe DC resistance from center conductor to outer conductor is 7.59 ± 0.50 ohms for the 1.0m length.
Standard cable uses 75Ω triaxial with fluoroethylene propylene (FEP) insulation. Available total probe lengths include 0.5, 1, 1.5, 2, 3, 5, or 9 meters. Extended temperature range cable uses perfluoroalkoxy (PFA) insulation. Length options for PFA are 0.5, 1, 1.5, 2, 5, or 9 meters.
Optional armor uses flexible AISI 302 or 304 SST with an FEP outer jacket. The connector material is gold-plated brass or gold-plated beryllium copper.
Tensile Strength Ratings
The Bently Nevada 330106-05-30-10-02-05 has specific maximum tensile strength ratings:
Therefore, always handle the probe carefully during installation. Never pull directly on the cable. Use the probe case for tension relief.
Temperature & Environmental Parameters
Standard operating and storage temperature ranges from -52°C to +177°C (-62°F to +350°F).
Extended temperature range capabilities:
A critical warning: exposing the probe below -34°C (-30°F) for a sustained period may cause premature failure of the pressure seal.
Probe relative humidity performance: less than a 3% change in Average Scale Factor (ASF) when tested at 93% humidity per IEC standard 68-2-3 for up to 56 days.
Pressure Sealing Information
The Bently Nevada 330106-05-30-10-02-05 seals differential pressure between probe tip and case. A Viton® O-ring provides this sealing function.
Important note: probes are not pressure tested prior to shipment. Contact the custom design department if your application requires a pressure seal test.
Mechanical Specifications
Probe weight is 323 g per meter (11.4 oz per meter). For the 1.0m length, the probe weighs approximately 0.32 kg.
Hazardous Area Approvals
With proper installation barriers or isolators, this probe supports:
Class I, Zone 0 and Zone 2 installations
Class I, Divisions 1 and 2, Groups A, B, C, D
Class II and Class III environments
Always refer to the relevant approval drawings for barrier or isolator requirements.
Installation Guidelines
Follow these steps for proper installation:
First, verify the M10x1 threads match your mounting hole.
Next, check the maximum thread engagement of 15 mm.
Then, apply recommended torque without exceeding limits.
Finally, secure the ClickLoc connector until you hear a click.
Additionally, consider whether your application needs optional armor. Armor adds protection in high-wear areas. However, it also increases cable stiffness.
Packaging List
1 x Bently Nevada 330106-05-30-10-02-05 probe assembly (1.0m standard cable)
1 x Miniature ClickLoc coaxial connector (pre-installed)
1 x Installation reference card
Note: No certificates or warranty documents are included.
Shipping method: Fedex, UPS, DHL
Frequently Asked Questions (FAQ)
1. What is the difference between standard and extended temperature range cable?
Standard cable uses FEP insulation rated to 177°C. Extended range cable uses PFA insulation. The PFA version allows tip temperatures up to 218°C and cable/connector temperatures up to 260°C.
2. Can I order the 330106-05-30-10-02-05 with armor?
Yes, armor is optional on both standard and extended temperature cables. Armor uses flexible AISI 302 or 304 SST with an FEP outer jacket. Specify your requirement at order time.
3. Is the probe pressure tested before shipment?
No, it is not. Bently Nevada does not perform pressure testing on standard probes. Contact their custom design department if your specific application requires a pressure seal test.
4. What happens if I exceed the tensile strength rating?
Exceeding 330 N at the probe case or 270 N at the connectors may damage the internal cable connections. This damage often leads to intermittent signals or complete probe failure.
5. Does the M10x1 thread option fit standard 3300 XL mounting holes?
Most 3300 XL applications use either 3/8-24 or M10x1 threads. Verify your mounting hole thread type before ordering. The two thread types are not interchangeable without adapters.